67 - Fire Inspector II Exam Questions and Answers

Question 1

Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.

Options:

A.

2

B.

3

C.

4

D.

5

Question 2

Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

Options:

A.

Group I-2

B.

Group A-1

C.

Office spaces

D.

Libraries in Group E

Question 3

All new building construction must have installed an approved water supply for fire protection which provides a minimum of:

Options:

A.

the required fire flow for fire protection.

B.

a static pressure of 40 psi at each hydrant.

C.

a static pressure of 60 psi at each hydrant.

D.

250 gal. per minute at the fire-access outlet.

Question 4

Horizontal exits shall not comprise more than ___ of the required exits from any floor area in a Group I-2 occupancy.

Options:

A.

1/3

B.

1/2

C.

2/3

D.

3/4

Question 5

When investigating a complaint of a violation within an occupied public area, the fire inspector:

Options:

A.

must give prior notice to the occupant.

B.

need not give prior notice of the inspection to the occupant.

C.

must provide the occupant with at least 24 hours of advance notice.

D.

must either give prior notice to the occupant or obtain an inspection warrant.

Question 6

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Question 7

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

Options:

A.

50

B.

75

C.

100

D.

150

Question 8

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Question 9

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

Options:

A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Question 10

The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.

Options:

A.

50

B.

75

C.

115

D.

150

Question 11

The minimum working space width for a 66-in. wide electrical equipment panel shall be in

Options:

A.

30

B.

36

C.

66

D.

78

Question 12

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

Options:

A.

They become a public record.

B.

They are time-consuming to complete and file.

C.

They may not address all of the code violations which may be encountered.

D.

They may serve as a basis for legal appeal against the code official's actions.

Question 13

Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.

How long must records related to this decision be maintained by the code official?

Options:

A.

Five years

B.

Three years

C.

Until the building is sold

D.

For as long as the building and the condition exist

Question 14

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

Options:

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Question 15

Compressed natural gas (CNG) motor vehicle fuel-dispensing equipment may be installed in which of the following locations?

Options:

A.

40 ft. from trolley wires.

B.

15 ft. from a public street.

C.

20 ft. from a railroad track.

D.

5 ft. from an undeveloped property line.

Question 16

A code official may allow the occupant load of a building or room to exceed that specified in the building code if additional exit facilities are provided, all other egress requirements are met, and the maximum occupancy does not exceed one occupant per sq. ft. of occupiable floor area.

Options:

A.

3

B.

5

C.

7

D.

10

Question 17

Given: In automobile refinishing spray booths where drying by heat is done in the spray booth, the spray booth shall be equipped with interlocks between the spraying and drying apparatus and the ventilating system.

These interlocks shall be arranged to purge the spray vapors from the spray booth for a minimum period of __ minutes before the drying apparatus can be operated.

Options:

A.

2

B.

3

C.

4

D.

5

Question 18

How long should the fire prevention bureau maintain fire inspection records on a commercial structure?

Options:

A.

For the life of the building.

B.

A maximum of five years.

C.

Until the building is renovated or has a change of occupancy.

D.

At least one year or until the next fire inspection, whichever is later.

Question 19

Quantities of flammable liquid storage in a control area of an Industrial Occupancy may be doubled when:

Options:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Question 20

Two tents which each have an area of 20,000 sq. ft. shall be separated from each other by a distance of not less than:

Options:

A.

0 ft. (no separation is required).

B.

10 ft.

C.

20 ft.

D.

25 ft.

Question 21

A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal. LP-gas tank must be separated a minimum of __ ft. from adjoining property.

Options:

A.

5

B.

10

C.

20

D.

25

Question 22

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Question 23

A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?

Options:

A.

1

B.

2

C.

3

D.

4

Question 24

For Halon 1211 hand-hose-line systems, all hoses for high-pressure systems must be tested at __ psi

Options:

A.

600

B.

900

C.

1,500

D.

2,500

Question 25

Given: Scheduling inspections should be done to obtain a high level of efficiency. When scheduling inspections at multiple occupancies on the same day, the inspector should:

Options:

A.

only identify critical violations.

B.

set limits on the time spent at each occupancy.

C.

select occupancies in the same general area.

D.

select occupancies with historically low violations.

Question 26

The occupant load of an R-2 building's common patio area is to be calculated using the value:

Options:

A.

50 net per person.

B.

11 gross per person.

C.

15 gross per person.

D.

assigned by the code official.