Winter Sale- Special Discount Limited Time 65% Offer - Ends in 0d 00h 00m 00s - Coupon code: netdisc

EMC DES-4122 Specialist - Implementation Engineer PowerEdge Version 2.0 Exam Practice Test

Page: 1 / 6
Total 60 questions

Specialist - Implementation Engineer PowerEdge Version 2.0 Questions and Answers

Question 1

A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

Question # 1

Options:

Question 2

You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

Question # 2

Options:

Question 3

For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

Question # 3

Options:

Question 4

What happened on April 30, 2019?

Question # 4

Question # 4

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

Question # 4

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question 5

For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.

When you have finished using the simulator, click Next.

Question # 5

Options:

Question 6

What can be done using in-band management?

Options:

A.

Agentless discovery

B.

Firmware and driver updates

C.

Network bandwidth optimization

D.

Remote access

Question 7

You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?

Options:

A.

RAID 0

B.

RAID 5

C.

RAID 1

D.

Non-RAID Mirroring

Question 8

What is the minimum number of components, beside the system board, required to POST?

Options:

A.

PSUs, CPUs, and DIMMs as configured in BIOS

B.

1 PSU, 1 DIMM, and 1 CPU only

C.

1 PSU and 1 CPU only

D.

1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller

Question 9

A Dell EMC PowerEdge server logs the following CPU Machine Check error CPU1 IERR What action might solve the problem?

Options:

A.

Remove flea power

B.

Update the Intel driver

C.

Reseat the IDSDM

D.

Swap the PERC controller

Page: 1 / 6
Total 60 questions