New Year Special Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

EMC DES-1721 Specialist - Implementation Engineer-SC Series Exam Exam Practice Test

Page: 1 / 15
Total 147 questions

Specialist - Implementation Engineer-SC Series Exam Questions and Answers

Question 1

Which method can be used to identify the server HBA WWN?

Options:

A.

Brocade Web Tools “Port Admin” tab

B.

Dell Storage Manager Data Collector

C.

Dell Storage Manager Client

D.

QConverge Console GUI

Question 2

The SC configuration consists of a SC7020, two (2) FC switches and four (4) Servers with a dual port FC HBA. How many zones are required for the SC to run with virtual port mode enabled?

Options:

A.

2

B.

4

C.

6

D.

8

Question 3

What is the name of the out-of-band system management connection for SC9000 systems?

Options:

A.

iDRAC

B.

MMC

C.

IPMI

D.

iLo

Question 4

Which SC Series array feature allows all front-end ports to act as active data paths?

Options:

A.

Dual Fabric

B.

ALUA

C.

Virtual Port Mode

D.

Legacy Port Mode

Question 5

How many SAS ports are used on each EMM of an SC460?

Options:

A.

1

B.

2

C.

3

D.

4

Question 6

Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts for switches that incorrectly negotiate speed and duplex?

Options:

A.

Use a separate supernet or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a blocking design

B.

Use a separate VLAN or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a non-blocking design

C.

Use a separate VLAN or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a non-blocking design

D.

Use a separate subnet or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a blocking design

Question 7

You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by the SC Series array?

Options:

A.

One port on each of the Ethernet switches

B.

Two ports on each of the Ethernet switches

C.

Four ports on each of the Ethernet switches

D.

Eight ports on each of the Ethernet switches

Question 8

What is the correct sequence of steps to present a volume to an ESXi host?

Question # 8

Options:

Question 9

After the implementation of a DR site with Synchronous replication all applications were up and running fine. The restore points were saved and validated; DR was predefined and successfully tested. Sometime later, one of the applications became unresponsive and initial troubleshooting points to Storage/Volume as the root cause.

Concerning the Replication to the DR site, what could be happening?

Options:

A.

Customer must switch to asynchronous replication as volumes tied to applications should not be synchronous replicated.

B.

The synchronous replication has been set to High Consistency and the link between the two sites is down.

C.

Unresponsive applications cannot be related to any DR or Replication practices

D.

Only asynchronous replication can possibly have a negative impact to volumes and applications if the link is down

Question 10

Refer to the exhibit.

Question # 10

When scanning Fibre Channel on a QLogic HBA what information can be obtained?

Options:

A.

The volume mapped to the QLogic HBA

B.

WWN of the QLogic HBA

C.

WWN of the connected Storage Center

D.

WWN of the SAN switch

Question 11

When an RS-232 serial cable is connected between a service laptop and SC Series hardware, which parameters need to be selected?

Options:

A.

Baud Rate = 9600, Parity = NoneData Bits = 8, Stop Bits =1, Flow Control = XON/XOFF

B.

Baud Rate = 115200, Parity = NoneData Bits = 8, Stop Bits = 1, Flow Control = XON/XOFF

C.

Baud Rate = 115200, Parity =NoneData Bits = 8, Stop Bits = 1, Flow Control = None

D.

Baud Rate = 115200, Parity = EvenData Bits = 8, Stop Bits = 1, Flow Control = XON/XOFF

Question 12

A customer has a volume that was created with the wrong datapage size. What is the simplest and least disruptive method to change this volume’s page size?

Options:

A.

Copy the volume, then mount the new volume

B.

Mirror the volume, then mount the mirrored volume

C.

Mirror the volume, then migrate to mirror

D.

Migrate the volume, then delete the source volume

Question 13

Match the Snapshot type with the description related to Snapshot creation.

Question # 13

Options:

Question 14

During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?

Options:

A.

Configure this host to access a Storage Center

B.

Configure VMware vSphere to access a Storage Center

C.

Discover and Configure Uninitialized SCv2000 or SC7000 Series Storage Centers

D.

Login to a Storage Center or Data Collector

Question 15

What is the HDD size that enforces dual redundancy?

Options:

A.

2 TB and higher

B.

Up to 3 TB

C.

4 TB and higher

D.

3 TB and higher

Question 16

You just finished racking a SC7020 array. After powering it on, you notice there is no indicator LED on the front or back of the array, but the fans are spinning.

What could be the cause?

Options:

A.

220VAC is being used. The system is preventing a fire hazard

B.

Controllers are misplaced. Swap the position of the controllers

C.

110VAC is being used on the power mains

D.

The SC is overheated; let it cool down

Question 17

A company is using an SC7020 array and the storage administrator wants to expand the available capacity by adding 48, 3.5” disk drives. Which expansion enclosures can be used to meet the demand?

Options:

A.

2x SC220 drive bays

B.

2x SC420 drive bays

C.

4x SC200 drive bays

D.

4x SC400 drive bays

Question 18

You are testing a new SC7020 storage array. You decided to deploy a temporary installation of Dell Storage Manager (DSM) Data Collector with an embedded database. What is the maximum number of days in which array information can be retained?

Options:

A.

15 days

B.

30 days

C.

60 days

D.

90 days

Question 19

Which redundancy option is available for drives on an SC7020 storage array?

Options:

A.

Dual redundancy is the default for all drives

B.

Single redundancy is the default for all drives

C.

Single or dual redundancy for 1.8 TB up to 3.9 TB drives

D.

Single or dual redundancy for 4 TB and higher drives

Question 20

An alert for a failed disk is visible under the alerts tab. Where would someone navigate to, in Unisphere Central for SC Series to identify the failed drive and have a graphical representation showing where in the enclosure the failed drive is located?

Options:

A.

System menu, Hardware submenu, Disks

B.

Hardware tab, then Enclosure in navigation tree

C.

Storage menu, Disks

D.

Storage tab, then Disks in the navigation tree

Question 21

What is a minimum recommended redundancy to support Controller port level failover?

Options:

A.

Two Fault Domains with two ports each

B.

Four Fault Domains with one port each

C.

Two Fault Domains with one port each

D.

One Fault Domain with four ports

Question 22

You are trying to discover a brand new SCv3020 but the process if failing. DHCP is not available. What is the best solution for this issue?

Options:

A.

Enable MTU and flowcontrol on the switch

B.

Configure IPv4 address on the system running the DSM Client on the target subnet

C.

Set BMC IPs

D.

Configure IPv4 on DSM Client machine and enable IPv6 addressing

Page: 1 / 15
Total 147 questions