Which method can be used to identify the server HBA WWN?
The SC configuration consists of a SC7020, two (2) FC switches and four (4) Servers with a dual port FC HBA. How many zones are required for the SC to run with virtual port mode enabled?
What is the name of the out-of-band system management connection for SC9000 systems?
Which SC Series array feature allows all front-end ports to act as active data paths?
How many SAS ports are used on each EMM of an SC460?
Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts for switches that incorrectly negotiate speed and duplex?
You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by the SC Series array?
What is the correct sequence of steps to present a volume to an ESXi host?
After the implementation of a DR site with Synchronous replication all applications were up and running fine. The restore points were saved and validated; DR was predefined and successfully tested. Sometime later, one of the applications became unresponsive and initial troubleshooting points to Storage/Volume as the root cause.
Concerning the Replication to the DR site, what could be happening?
Refer to the exhibit.
When scanning Fibre Channel on a QLogic HBA what information can be obtained?
When an RS-232 serial cable is connected between a service laptop and SC Series hardware, which parameters need to be selected?
A customer has a volume that was created with the wrong datapage size. What is the simplest and least disruptive method to change this volume’s page size?
Match the Snapshot type with the description related to Snapshot creation.
During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?
What is the HDD size that enforces dual redundancy?
You just finished racking a SC7020 array. After powering it on, you notice there is no indicator LED on the front or back of the array, but the fans are spinning.
What could be the cause?
A company is using an SC7020 array and the storage administrator wants to expand the available capacity by adding 48, 3.5” disk drives. Which expansion enclosures can be used to meet the demand?
You are testing a new SC7020 storage array. You decided to deploy a temporary installation of Dell Storage Manager (DSM) Data Collector with an embedded database. What is the maximum number of days in which array information can be retained?
Which redundancy option is available for drives on an SC7020 storage array?
An alert for a failed disk is visible under the alerts tab. Where would someone navigate to, in Unisphere Central for SC Series to identify the failed drive and have a graphical representation showing where in the enclosure the failed drive is located?
What is a minimum recommended redundancy to support Controller port level failover?
You are trying to discover a brand new SCv3020 but the process if failing. DHCP is not available. What is the best solution for this issue?